دوره 9، شماره 1 - ( 10-1397 )                   جلد 9 شماره 1 صفحات 37-19 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mohebbi M, Dadkhah H. OPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES. International Journal of Optimization in Civil Engineering 2019; 9 (1) :19-37
URL: http://ijoce.iust.ac.ir/article-1-373-fa.html
OPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES. عنوان نشریه. 1397; 9 (1) :19-37

URL: http://ijoce.iust.ac.ir/article-1-373-fa.html


چکیده:   (17981 مشاهده)
Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, the base stiffness and the weighting parameter of H2/linear quadratic Gaussian control algorithm, which is used to determine the desired control force, have been considered as the design variables and different earthquake records have been considered as design earthquakes. First, the optimum values of these variables under each of the considered earthquakes have been determined by using the genetic algorithm and then, an optimum control system has been designed with multiple earthquakes-based design approach. The defined design objective is minimizing the peak base drift while the peak inter-story drift has been constrained. For numerical simulation, smart base isolation system is designed for controlling a four-story shear frame. The results show that when the control system designed for a specific earthquake is subjected to another earthquake, difference between the performance of this control system and the optimal case under that earthquake is considerable. Hence, the specific earthquake-based design approach is an inappropriate design procedure for smart base isolation. Also, it has been found that control system designed based on multiple earthquakes-based design approach shows effective performance in controlling the response of structure under a wide range of earthquakes.
متن کامل [PDF 550 kb]   (4531 دریافت)    
نوع مطالعه: پژوهشي | موضوع مقاله: Optimal design
دریافت: 1397/3/11 | پذیرش: 1397/3/11 | انتشار: 1397/3/11

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به دانشگاه علم و صنعت ایران می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Iran University of Science & Technology

Designed & Developed by : Yektaweb